by ecuedit » Tue Apr 17, 2012 11:28 pm
Hi there,
I have made a quick look at your file. I will take some more time to analyze tomorrow.
For now I have some major things:
You can set single value rail diagnostic limiter to 1500bar (dark area).
Last col in ID map is for cold start, you should leave it intacked.
Remove one not needed column, move others to the left and do the recalculation.
SVRPLs are OK.
I would not increase SOI so much
TL - why did you set it so high?
The whole thing is overfueled, you are injecting a lot of fuel but no air
Smoke map has to be done and recalculated
DW is OK
Rail pressure value is nice
Rail map can be done better