yan.ko wrote:Oops, you are right, duration is rail vs iq. Mea culpa
OK.
So, SOI map (sorry - how to tranlate abbreviature SOI?) has no any data around map, that i can use as axis values.
Any axises values in hex seems as: type_of_data number_values_N value1 value2 ... valueN
All "right" axises - has values before map.
Rail pressure precontrol 8x8 (x69688), RPM vs rail
axises start from
x69660: 50222 00008 00200 00500 00750 ... 04000 ; 50222= RPM, factor = 1
x69674: 51128 00008 02000 03000 05000 ... 13000 ; 51128 = rail pressure, factor = 0,1
For EGR map 16x16 (x61E78), values of RPM and IQ
x61E30: 50222 00016 00830 01100 01350 01400 01450 ... 02650; 50222 = RPM
x61E54: 50158 00016 00000 00200 00400 00800 01000 01200 01400 ... 04500; 51158 = IQ, factor =0,01
OK.
I see in video, what values for SOI map (IQ vs RPM) (16x16) are:
X-axis: RPM : 200, 400, 600, 800 ...
So, i must to find "00016 00200 00400 00800"
may be "50222 00016 00200 00400 00800"
BUT BEFORE SOI map there are not ANY values like that.
There are more maps without axises values.
x62816 SOI 1
x69848 Rail pressure
x69c70 Rail pressure limiter
x6afe2 SOI 2
plus 4 parralel paps in second memory databank: x7....
There I can find this values?
That I do wrong?