juice wrote:I replace only the NOZZLES, the interior of CR injector is activated electronically, and my non-cr is activated by pressure..by nozzles in the final is the same..indifferent how the fuel goes to nozzle, the nozzle is there
juice wrote:On nozzles 320d 136 i see "DLLA 145 P 748" and the other side i see number 18319. I dont know yet about other nozzle.
javizzz wrote:juice wrote:On nozzles 320d 136 i see "DLLA 145 P 748" and the other side i see number 18319. I dont know yet about other nozzle.
the 320d 136cv uses 6 holes x 0.22mm at 145º spray angle nozzles and the 320d 150cv uses 6 holes x 0.16mm at 160º............
so, no, obviously they are not the same (different size whit different spray angle)..............
juice wrote:javizzz wrote:juice wrote:On nozzles 320d 136 i see "DLLA 145 P 748" and the other side i see number 18319. I dont know yet about other nozzle.
the 320d 136cv uses 6 holes x 0.22mm at 145º spray angle nozzles and the 320d 150cv uses 6 holes x 0.16mm at 160º............
so, no, obviously they are not the same (different size whit different spray angle)..............
Great info man, thanks a lot..well i think i` will search a pair of bosio or firad with the same specs but bigger holes, ..because from the pump i cant squeeze more than 65 mg..even if i put request to 80 mg and it shows to me on tester full load 80 mg..the real pump iq from some dyno tests seems to be 65 = ~165 hp
juice wrote:Neah, problem is not the limiters. I removed all limiters, i made logs and actual fuel IQ is there, to 68 mg . The main limiter on my ecu is torque limiter. I can request 75 mg, in logs i see 75 mg, but in pump maybe will not be 75. there is not about limiters, is about pump and injectors physical limit.