EDC16 pd105

Posts related to map selection, map location, correct map treatment.

Re: EDC16 pd105

Postby kinetic » Fri Oct 26, 2012 8:03 pm

cstefan wrote:its fine now, i dont know what i have been doing wrong, 2 more question, what is the z axis factor?and witch codeblock im using since they are one for manual and one for automatic? thnks in advance

Mod one block, test and see, easy. The map is beggining of injection, basically it sets nozzle opening point before TDC, for high IQs obvioustly. Solenoid in injector manage this, u can read all about it on edc16 vag self studie. Z axis is time in "us", aplly correct factor and u will see crank angles BTDC.

kinetic
Bronze
 
Posts: 27
Joined: Mon Oct 22, 2012 4:52 pm
Location: Portugal

Re: EDC16 pd105

Postby cstefan » Fri Oct 26, 2012 8:41 pm

so z factor is cranck angle in degrees like the edc15 right? factor 0.023437?

cstefan
Bronze
 
Posts: 34
Joined: Sat Oct 20, 2012 4:21 am
Location: Portugal

Re: EDC16 pd105

Postby kinetic » Sat Oct 27, 2012 1:42 am

For edc15P 0.023437 is not right for degrees in soi maps, just for IOT calibration tables. But in edc16 yes u r right, apply factor and u will see it makes sense.

Admin, about image, i uploaded after 3 posts, will try again tomorrow 2 b sure. Tks