Hi all,

I'm trying to figure out why engine fans run when I start the engine even when it's cold.
This started after installing a straight through exhaust and deleting the DPF and EGR and all cats along with EGT and O2 sensors.
The only sensors I'm keeping are the EGT #1 and O2 #1

As far as I know my DPF solution is good however I suspect this issue is because the EGT sensors have been deleted. There are no error codes in the ECU.
Also are there any maps that need to be disabled when removing the NOx storage catalyst.

The car is a 2009 Jetta TDI CR140
CBEA Engine

I'm attaching original and mod files for comparison.

I've been trying to solve this issue for a while so any help is greatly appreciated.
Thanks
You do not have permissions to view the files yet. You have to be registered and you have to make at least 3 quality / unique posts.

olderon
New user
 
Posts: 7
Joined: Sat Sep 14, 2019 7:21 am
Location: united states

Re: EDC17CP14 fans run when engine on

Postby selveti7 » Fri Aug 27, 2021 12:36 am

DPF WAS NOT CORRECTLY REMOVED

I CORRECTED YOUR FILE BUT HERE IS WHAT I WANT YOU TO DO FIRST MAKE SURE THAT CABLES AND SENSORS IN YOUR DPF AND EGR ARE PLUGED IN AS ORIGINAL AND LEAVE THEM ALL PLUGED IN AND UPLOAD YOUR ORIGINAL FILE IN THE CAR AND SWITCH ON IGNITION DELETE FAULT CODES THAN UPLOAD THE FILE I CORRECTED AND YOU WILL BE FINE GOOD LUCK
You do not have permissions to view the files yet. You have to be registered and you have to make at least 3 quality / unique posts.

User avatar
selveti7
Gold
 
Posts: 147
Joined: Sat Feb 06, 2021 11:23 pm
Location: Switzerland

Re: EDC17CP14 fans run when engine on

Postby olderon » Tue Sep 07, 2021 5:54 am

Posting a follow up in case someone is wondering what the solution was.
The fans were running because of one of the EGT sensors.
When I plugged in the EGT sensor prior to precatalytic converter (brown connector) the fans stopped running.

If someone knows how to disable that EGT sensor in software please let me know.

Thanks

olderon
New user
 
Posts: 7
Joined: Sat Sep 14, 2019 7:21 am
Location: united states

Re: EDC17CP14 fans run when engine on

Postby Ninu » Fri Sep 17, 2021 1:02 pm

Have same issu on a Vag and it was after TVA off ( v157)... with an crack software. Good if you find solution.

Ninu
New user
 
Posts: 7
Joined: Fri Sep 17, 2021 12:51 pm
Location: France

Re: EDC17CP14 fans run when engine on

Postby Humbletnr » Sat Sep 18, 2021 12:48 pm

olderon wrote:Posting a follow up in case someone is wondering what the solution was.
The fans were running because of one of the EGT sensors.
When I plugged in the EGT sensor prior to precatalytic converter (brown connector) the fans stopped running.

If someone knows how to disable that EGT sensor in software please let me know.

Thanks


Please report back on the success!
You do not have permissions to view the files yet. You have to be registered and you have to make at least 3 quality / unique posts.

Humbletnr
New user
 
Posts: 5
Joined: Sat Feb 16, 2019 8:20 pm
Location: Europe


Return to General tuning

Who is online

Users browsing this forum: No registered users and 7 guests