I wasn't very clear actually, when i say I'm limited by something I mean I get limited by a map or a single value limiter :)
I just calculated something that should be Air Fuel Ratio.. Look at the pictures.
As you can see, what I did in step 13 makes it run
very lean above 1000mg of air, that's why I don't reach an IQ of 70 in my logs.
Stock:Stock_smoke_afr.png
Step13:Step13_smoke_afr.png
About calculations....I did this: AFR=(Airflow)/(IQ*0,84) because Airflow is mg and IQ is mm3. And 1mm3 of diesel is 0,84mg.
Feel free to correct me ;)
I still feel that this calculation is NOT correct. Because Airflow is measured in mg/pulse and IQ is mm3/stroke.
IF
1stroke=1pulse, then my calculations are right.
But I don't think so...
That pulse thing may be constant or it may be tied to rpm, like 1 pulse every revolution... :?:
But 1 revolution has 2 injection strokes, meaning 1pulse=2strokes.. :?: :?: